120 Minutes Fire Resistance to a Steel Stud Internal Partition

Typical Examples of Fire Rated Constructions Using VERSA TECBOR®

Versapanel - Metal Partition - 60 minutes
Steel Partitions Overall Width: 95mm

Facing 12mm Versa Tecbor® to each face
A. Double Steel Stud on ‘H` 70mm x 36mm x 0.6mm
B. Steel Stud on ‘C` 75mm x 50mm x 0.6mm
(Alternative test assessed by Warrington Fire Ltd
based on the original ‘H` test)
Self tapping screws 3.5mm x 35mm
at 200-250mm, Joint paste
(to all joints and screw heads)

Framing Steel Stud on ‘C` 75mm x 50mm x 0.6mm, Metal         
Track 73mm x 36mm x 0.5mm, M6 fixings at 250 - 300mm

Infill Mineral Wool RW3 70mm
(1 layer 30mm, 1 layer 40mm with joints staggered)

Tested in accordance to EN 1364-1