120 Minutes Fire Resistance to a Timber Stud Internal Partition Typical Examples of Fire Rated Constructions Using VERSA TECBOR® Facing 12mm Versa Tecbor® to each face Framing 75 x 50mm Timber Stud Infill Mineral Wool RW3 70mm Tested in accordance to EN 1364-1 Typical Example - Alternative to Steel Stud |

Timber Partitions Overall Width: 99mm