180 Minutes Fire Resistance to a Timber Stud Internal Partition

Typical Examples of Fire Rated Constructions Using VERSA TECBOR®

Versapanel - Metal Partition - 60 minutes
Timber Partitions Overall Width: 115mm

Facing 10mm + 10mm Versa Tecbor® to each face

Framing 75 x 50mm Timber Stud

Infill Mineral Wool 60mm, density 100kg/m3
(1 layer 30mm, 1 layer 30mm with joints staggered)

Tested in accordance to EN 1364-1

 Typical Example - Alternative to Steel Stud