Typical U-Value Calculations for Ufoil-VBF™ when used with timber frame standard partition wall construction.
| Typical U-Value Calculations for Timber Frame (95mm) |
| 95mm Timber Stud with Render |
Thickness
(mm) |
Thermal
Conductivity
(W/mk) |
Thermal
Resistance
(m2 K/W) |
| Outside surface resistance |
- |
- |
0.040 |
| Render (BS5250) |
19.0 |
0.800 |
0.024 |
| Blockwork Light |
100.0 |
0.270 |
0.370 |
| Cavity |
50.0 |
- |
0.665 |
| Ufoil-VBF |
5.0 |
- |
0.125 |
| Plywood |
9.5 |
0.130 |
0.073 |
| High Performance Glass Fibre |
95.0 |
0.033 |
2.879 |
| Polythene 1000 gauge |
- |
- |
- |
| Gyproc Wallboard |
12.5 |
- |
0.070 |
| Inside surface resistance |
- |
- |
0.130 |
U-VALUE 0.27 W/m2K |
|
|
 |