Standard
panel size is 2400mm x 1200mm although Versafire® is available in 1830 x 915 for the application of
fire door blanks.
*Can
be fixed at 600mm centres providing the fixings are at
200mm centres / 250mm centres maximum and that they are
staggered. All edges must be supported.
| Density
(average) |
1100
Kg/m3 |
Product
Tolerances
Thickness
Width
Length
Squareness |
-0.20mm to +0.40mm
-2.00mm to +2.00mm
-2.00mm to +2.00mm
5.00mm on diagonal difference |
| Bending
Strength |
13.7N/mm2 |
| Permissable
Design Value |
3.4N/mm2 |
| Surface
Alkanility |
9.5pH |
| Thermal
Conductivity |
0.124W/mk |
Bonding
Agent
Versafire is odourless and bonding agent is
free from formaldehyde |
Fire
Rating
Tested to BS476 part 4 and is Non-Combustible.
Also tested to BS EN ISO 1716 & 1182 -
rated A1 Non Combustible. |
|
Acoustic
Insulation
| Versafire® Accoustic Insulation Test |
9mm Versafire® board to Each Face
75mm Steel Stud Sections
60Kg Density Mineral Wood to Cavity
Test result 38dB on average |
|
Dimensional
Stability
| Test
Item |
Unit |
Test
Result |
| Thickness
Swelling |
| After
24 Hours Immersion |
% |
0.2% |
| After
Freeze/ Thaw Test |
% |
-0.1% |
| Moisture
Exposure Elongation Rate |
% |
<0.9% |
| Water
Absorption |
% |
32% |
| Heat
Exposure Deformation Rate |
% |
<0.2% |
|
Freeze/Thaw Test
Frozen at -17.5°c + 2.5°c continuously for over 16 hours. Kept frozen at -17.5°c for 4 hours. Thawed by immersing in water at approximately 20. Maintained at a temperature of 20°c ± 3°c for 5 hours. Freeze and thaw cycle is repeated 10 times.
Test result: No cracking, disintegration, crumbling, stripping occurs on the Board and it achieves the Freeze/thaw value of 1.97%
Water Endurance Test
No bloating on reverse side. Non-occurrence of swelling, breakage nor tearing apart of the board.
Compressive Strength
Conditioning:
Unless otherwise specified, all test specimens were conditioned at 23 + 2°C, 70 + 15% relative humidity and tested
at 23 + 2°C, 50 + 5% relative humidity.
Test Result:
Test |
Unit |
Versafire |
Compressive Strength, Average |
N/mm2 |
8.3 |
Water Vapour Transmission
Adpodted BS EN ISO 12572 : 2001 Hygrothermal Performance Of Building Materials and Products
Determination of Water Vapour Transmission Properties
Cross-reference : BS EN 12086 : 1997
Thermal Insulating Products For Building Applications
Determination Of Water Vapour Transmission Properties
Conditioning:
Unless otherwise specified, all test specimens were conditioned at 23 + 2°C, 70 + 15% relative humidity and tested
at 23 + 2°C, 65 + 5% relative humidity.
Test Result:
Test |
Unit |
Versafire |
Water Vapour Transmission, Average |
g/m2.day |
48.1 |
|