The
Versaliner™ JPM 6mm is first fixed
to the substrate according to these working
recommendations.
The
Versaliner™ JPM 6mm must be dry, firm
and free from dust and release agent.
A
priming coat of Ardex
P 51 is recommended (mixing
ratio 1:1 with water), ready for tiling
after one hour. |
|
 |
|
At
places with high exposure to damp (e.g.
domestic bathrooms) sealing with Ardex
Sealant S1-K* or Ardex
Sealant WPC is necessary.
The
sealants are applied in two coats with a
roller or spreader knife.
At
vulnerable places (e.g. corners of the shower)
ARDEX Sealing Tape should be laid in the
first coat using the adhesive effect of
the sealant, then a second coat should be
applied (rolled on).
If
a sealant is used, priming is not necessary. |
|
|