30
Minutes Fire Resistance To A Metal Stud
Partition One Side
- Option C
Typical Examples Of Fire Rated Constructions Using Cement
Bonded Particleboard
Metal
Partition
- Framework - 70mm
x 35mm x 0.7mm lightweight rectangular hollow steel
studs at 400mm nominal centres with 70mm x 30mm
x 0.7mm steel channel studs at both end head and
foot of the framework. Fixed at 300mm centre with
non-combustible fixings.
- Boarding
(Fire Side) - 10mm C.P.Board fixed to the metal
stud firstly applying panel bonding adhesive, to
the face of the studs, butt joint boards.
- Fixings - Using 35mm tek screws at 300mm centres.
- Boarding
(Non Fire Side) - 12mm plywood fixed at 300mm
centre with 35mm self tapping screws. 35mm foil
backed/foil faced polyurethane foam fixed to the
plywood using plastic insulation hangars at 600mm
nominal centres.
Overall
Width: 127mm
For
full construction details and relevent data on the above
systems please contact Euroform Products Limited.
|