60
Minutes Fire Resistance To A Metal Stud Partition
Typical Examples Of Fire Rated Constructions Using Cement
Bonded Particleboard
Metal
Partitions
- Framework - 50mm
x 32mm x 0.6mm galvanised steel channel studs at
610mm centres with head and base studs.
- Board - 12mm C.P.Board fixed each side of framework with
staggered butt joints, fixings at 300mm centre using
35mmm tek screws.
- Fillets - 100mm x 12mm C.P.Board strips on all face
of channel, fixed at 300mm centres with 35mm tek
screws.
- Insulation - 50mm x 60kg/m3 packed in-between studs. Mineral
fibre.
Overall
Width: 96mm For
full construction details and relevent data on the above
systems please contact Euroform Products Limited.
| Contact
Us |
| Euroform Products
Ltd, |
The
Heliport, Lyncastle Road, Appleton, Warrington WA4 4SN |
|
| Tel: +44
(0) 1925 860999 |
Fax: +44
(0) 1925 860066 |
Email: sales@euroform.co.uk |
Site Map
Due
to our policy of continuous development we reserve the right to change
design and specifications without prior notice. Euroform Products Limited
does not accept responsibility for any loss as a result of any company
or person relying on material on this website, or for any mistakes. Although
every care is taken to ensure accuracy, this website is a general guide
and specific technical advice is recommended before proceeding with any
transaction. Specific fact sheets, or, technical advice is available from
Euroform technical department 01925 860999. Copying or reproducing any
part of this website in any manner is not permitted without prior written
consent from Euroform Products Limited. |
Registered Office: Euroform Products Limited, Hillsborough Works, Langsett Road, Sheffield, S6 2LW Registered Number: 2945504 |
|